COMMERCIAL UPRIGHT
VACUUM CLEANER
OWNER’S GUIDE
800 SERIES
(Model SC899 pictured)
Index
Important Safeguards .................... 2
General Information....................... 6
Assembly....................................... 6
Use ................................................ 8
Fan Chamber .............................. 10
Dust Bag ..................................... 11
Brush Roll Belt............................. 12
Brush Roll (chrome steel) ............ 13
Brush Roll (anodized aluminum) 14
Headlight ..................................... 14
Warranty ...................................... 15
For location of nearest
Eureka/Sanitaire Warranty Station
or service information call
1-800-282-2886.
Grounding Instructions
This appliance must be grounded. If it should malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk of electric shock.
This appliance is equipped with a cord having an equipment-grounding conductor and
grounding plug. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
DANGER
Improper connection of an equipment-grounding conductor can result in risk of electric
shock. Check with a qualified electrician or service person if you are in doubt as to
whether the outlet is properly grounded. Do not modify the plug provided with the
appliance. If it will not fit the outlet, have proper outlet installed by a qualified technician.
This appliance is for use on a nominal 120 volt circuit and has a grounding plug that
looks like the plug illustrated in Figure A.A temporary adapter which looks like the adapter
illustrated in Figure B may be used to connect this plug to a two-pole receptacle, as
shown, if a properly grounded outlet is not available. The temporary adapter should be
used only until a properly grounded outlet, Figure A, can be installed by a qualified
electrician.The green colored rigid ear, lug, or the like extending from the adapter must
be connected to a permanent ground such as a properly grounded outlet box cover.
Whenever the adapter is used, it must be held in place by a metal screw.
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian
Electrical Code.
GROUNDED
GROUNDED
OUTLET BOX
OUTLET BOX
ADAPTER
GROUNDING BLADE
IS LONGEST OF THE
THREE BLADES
FIGURE A
FIGURE B
METAL
SCREW
GROUNDING
TAB
3
CONSEILS DE SÉCURITÉ
Lors de l’utilisation d’un appareil électrique, quelques précautions élémentaires doivent
être observées, incluant les suivantes:
LISEZ TOUTES LES INSTRUCTIONS AVANT D’UTILISER VOTRE ASPIRATEUR.
AVERTISSEMENT
Pour réduire le risque de feu, de choc électrique, ou de blessure:
• Ne pas utiliser à l’extérieur ou sur des surfaces mouillées.
• Fermez le commutateur et débranchez l’appareil lorsque vous ne l’utilisez pas ou avant
le nettoyage ou l’entretien.
• Ne permettez pas qu’il soit utilisé comme jouet. Une attention particulière est nécessaire
lorsque utilisé par ou près d’un enfant.
• Suivez les recommandations d’utilisation de ce manuel. Utilisez uniquement les
accessoires recommandés par le fabriquant.
• Ne pas utiliser si le cordon ou la fiche sont endommagès. Si l’aspirateur ne fonctionne
pas comme il le devrait, s’il a été échappé, s’il est endommagé, s’il a été laissé à
l’extérieur ou échappé dans l’eau, retournez-le à un centre de service avant de utiliser.
• Ne pas le tirer ou le transporter par le cordon, ne pas utiliser le cordon en guise de
poignée. Ne pas fermer une porte sur le cordon ou tirer le cordon sur des coins ou
bordures pointus. Ne pas circuler sur le cordon avec l’aspirateur. Tenir le cordon à
distance des surfaces chauffantes.
• Branchez toujours l’aspirateur dans une prise à trois (mise à la terre).
• Ne pas utiliser des rallonges ou des prises qui n’ont pas de capacité suffisante pour
transporter le courant.
• Fermer tous les contrôles avant débrancher.
• Ne pas débrancher en tirant sur le cordon. Pour débrancher, tenez la fiche et non le
cordon.
• Ne pas manipuler la fiche ou l’aspirateur avec les mains mouillées.
• Ne pas rien insérer dans les ouvertures. Ne pas utiliser si des ouvertures sont bloquées;
assurez-vous qu’elles soient dégagées de poussière, mousse, cheveux ou toute autre
chose qui pourrait réduire le passage de l’air.
• Cet aspirateur crée de la succion et contient un rouleau-brosse tournant.Tenir les parties
mobiles et les ouvertures loin des cheveux, du linge, des doigts et de toute partie du
corps.
• Ne pas ramasser des objets qui brûlent ou fument comme les cigarettes, alumettes ou
cendres chaudes.
• N’utilisez pas sans le sac de poussière en place.
• Les poulies du courroie peuvent devenir chaudes pendant l’utilisation normale. Pour
prevenir des brûlures, évitez de touché la poulie du courroie lorsque vous réparez la
courroie.
• Portez une attention particulière lorsque vous nettoyez les escaliers.
• Ne pas utiliser pour ramasser des liquides inflammables ou combustibles comme de
l’essence: Ne pas utiliser dans les endroits où ces liquides pourraient être présents.
• Entreposez votre aspirateur à l’intérieur dans un endroit propre et sec.
• Maintenez un bon éclairage à l’endroit où vous travaillez.
• Débrancher les appareils électrique avant de les balayer.
CONSERVEZ CES INSTRUCTIONS
4
INSTRUCTIONS VISANT LA MISE À LA TERRE
Cet appareil doit être mis à la terre. En cas défaillance ou de panne éventuelles, la
mise à la terre fournit au courant un chemin de moindre résistance qui réduit le
risque de choc électrique. Cet appareil est pourvu d’un cordon muni d’un
conducteur de terre et d’une fiche avec broche de terre. La fiche doit être branchée
dans une prise appropriée correctement installée et mise à la terre conformément
aux règlements et ordonnances municipaux.
AVERTISSEMENT
Un conducteur de terre mal raccordé peut entraîner un risque de choc électrique.
Consulter un électricien ou un technicien d’entretien qualifié si vous n’étes pas certain
que la prise est correctement mise à la terre. Ne pas modifier la fiche fournie avec
l’appareil-si elle ne peut être insérée dans la prise, faire installer une prise adéquate
par un électricien qualifié.
Note. Au Canada, l’utilisation d’un adaptateur temporaire n’est pas autorisée par le
Code canadien de l’électricité.
Cet appareil est destiné à un circuit de 120 V et est muni d’une fiche de mise à la terre
semblable à celle illustrée par le Figure A. S’assurer que l’appareil est branché à une
prise de courant ayant la même configuration que la fiche. Aucun adaptateur ne devrait
être utilisé avec cet appareil.
Boîte de Prise de Terre
LA LAME DE TERRE
EST LA PLUS LONGUE
DES TROIS LAMES
FIGURE A
5
GENERAL INFORMATION
The cleaner is designed to pick up dirt and dust particles. Avoid picking up hard or
sharp objects with the cleaner to prevent bag tears, hose clogs, and fan blade breakage
with subsequent motor damage.
Service Information
The instructions in this booklet serve as a guide to routine maintenance. For additional
service information telephone our toll free number for the nearest Eureka/Sanitaire
Authorized Warranty Station. Refer to The Sanitaire Commercial Warranty for complete
service information. You should know the model, type and serial numbers when
you call:
USA: 1-800-282-2886
Mexico: 5670-6169
Canada: 1-800-282-2886
DO NOT OIL the motor or the brush roll at any time. The bearings are
permanently lubricated and sealed.
Rating Plate
MODEL
VOLTS
TYPE
SERIAL NO.
HERTZ
The model, type, and serial numbers are
indicated on the rating plate located on
the underneath side of the cleaner. For
prompt and complete service information,
always refer to these numbers when
inquiring about service.
AMPS.
SERVICEINFORMATION:1-800-282-2886
Model & Type ____________________
Serial No. _______________________
B
A
HOW TO ASSEMBLE
Assembly Packet
The assembly packet is with the owner’s
guide. The packet contains two 2-part
bolts and two cord hooks. An extra drive
belt is also included with some models.
Step 1
Assemble the Handle
Slip the upper handle and the lower handle
together so the handle bolt holes align and
the slots in the handle are positioned as
shown in Detail A. Insert a 2-part bolt (A)
in the center of the handle and tighten.
C
Detail A
A
Hold the assembled handle so it curves
away from the cleaner. Then push the
handle into the handle socket (D) at the
rear of the cleaner. Align the holes, insert
the other 2-part bolt (A), and tighten.
D
6
Step 2
Attach Upper Cord Hook
Pull the spring on the electrical cord
upward toward the top of the handle.
Make sure slots in handle are positioned
properly, see Detail A.
B
Insert the lower half of the spring into the
upper cord hook (B), as shown. Snap the
hook into the upper handle, directions
below.
BAG
SUPPORT
HOOK
1. Place inner tab
into slot
2. Press hook
around handle
3. SNAP opposite inner
tab into place
Step 3
Attach Lower Cord Hook
Insert the power cord into the lower cord
hook (C), as shown. Snap the hook into
the lower handle. Pull up on the cord to
tighten but leave enough slack near the
base so the cord is not strained when the
handle is lowered. Wrap the cord around
the two cord hooks. Fasten the plug to
the cord to prevent unwinding.
F
E
Step 4
Install The Bag
Insert the bag adapter clip (E) on the
bottom of the bag collar into the bag
adapter retainer (F).
Push the bag collar up and forward so
the locator lug slides into the slot
indicated by the arrow. Then turn the
cam latch (G) to lock the bag onto the
rivet (H).
H
G
Loop the spring from the top of the bag
onto the bag support located to the back
of the upper cord hook (B).
7
HOW TO USE
The upright vacuum cleaner is designed to be used on multiple types of carpeting. Do
not attempt to use the upright vacuum cleaner on bare floors, as damage to the
floor covering may result. Above the floor cleaning tools are available (optional).
1. Store
2. Use
Handle Adjustment
With the tip of the foot, press down to
release the handle lock located at the left
rear side of the cleaner. Move the handle
and adjust it to the desired position for
(1) storing upright, (2) operating the
cleaner at a comfortable height for the
user, and (3) cleaning underneath low
3.Clean
Underneath
furniture.
Handle Lock
ON/OFF
Power Switch
The power switch is mounted on the
motor hood near the handle. Switch style
varies by model and may differ from the
illustration. A push with the foot turns the
motor ON; push again to turn the motor
OFF.
Edge Kleener®
Edge Kleener feature provides for improved cleaning of carpets near walls and stationary
furniture. Slots on the sides of the nozzle increase air flow to the edges of the cleaner
and add to the cleaning efficiency of the cleaner. To operate, simply run cleaner along
edge board. Edge Kleener operates instantly and automatically.
Cord Storage
The cleaner has two convenient cord storage hooks attached to the handle. Wind the
cord around the hooks and fasten the plug to the cord to prevent unwinding.
8
Cleaner Height Setting
WARNING: Avoid injury. Keep loose clothing, hair, fingers, and all other parts of
body away from any moving part (such as the revolving brush).Turn
off the switch and unplug the cleaner before changing the cleaner
height setting.
Adjust the vacuum cleaner height setting to match the carpet pile height. Refer to the
following chart of recommended settings for carpet types.
The front of the cleaner has either a knob
or slide adjustment which raises or
Recommended
Setting
Example of Carpet
lowers the cleaner base to match the
type of carpet. With the cleaner cord
unplugged, set the adjustment according
to the table as a starting point. While
the cleaner is off and disconnected
from the outlet, place the handle in the
operating position, tilt the cleaner back
to remove the weight from the wheels,
and adjust the setting. Then plug the
cleaner into the electrical outlet, turn on
the switch, lower the handle, and pass
the cleaner over the carpet. If the cleaner
is still difficult to push, follow the
procedure and test the cleaner at the
next higher setting. Continue testing the
setting until the cleaner is comfortable
to move. Moving the knob or slide to the
next higher setting raises the brush roll
slightly, making the cleaner easier to
push. However, the brush roll must make
contact with the carpet for effective
cleaning.
Position 1
Low pile as kitchen, indoor,
outdoor
Position 2
Position 3
Position 4
Sculptured
Plush or thick sculptured
Thick plush
If the cleaner has additional height settings, they are for thicker
carpets or where easier pushing is desired.
9
HOW TO MAINTAIN
The instructions given in this booklet serve as a guide to routine maintenance. To avoid
unnecessary service calls, check the bag, belt and brush roll often.
Quick Kleen® Fan Chamber
NOTE: Turn off the switch and unplug the electrical cord before cleaning.
The clear, removable fan chamber cover provides easy
inspection, cleaning, and maintenance of the fan
chamber. Removing the cover provides easy access to
the motor fan. Grease buildup, dirt, or other obstructions,
visible through the fan cover, should be removed. To
clean the fan area, take off the chrome bottom plate by
releasing the two cam locks (see Brush Roll Belt, Figure
1 and 2). Remove the belt from the motor pulley, then
loosen and remove the screws on either side of the fan
cover, as indicated by the arrows. Push the cam locks
outward against the wheels to lift the cover from the
cleaner base. Dirt and obstructions can easily be
cleared;however, caked grease may need to be scraped
from the cover and the cleaner. If the fan does not turn
freely, it also should be removed for cleaning. To remove the fan, place a wrench over
the motor pulley. Hold the fan blades with one hand and turn the wrench counterclockwise.
Remove the motor pulley and lift the fan off the motor shaft. Clean the area and replace
the fan over the motor shaft. Tighten the motor pulley snugly clockwise with the wrench.
If necessary, replace the fan cover or the gasket with replacement parts.
Be sure the gasket is in place. Reposition the fan cover by first placing the exhaust end
into place between the large rear wheels. Seat the fan cover firmly. Next replace the
belt and bottom plate as the pressure from the bottom plate helps seal the fan cover.
Start the two screws by hand to be sure they are straight, then tighten.
Order fan chamber cover replacement kit (fan cover, gasket, two screws) Part No.
52334.
Cleaner Care
NOTE: Turn off the switch and unplug the electrical cord before cleaning unit.
To keep the vacuum cleaner looking new, it can be wiped with a damp cloth and a mild
soap solution, then thoroughly dried. Never use any type of chemical as chemicals can
damage the cleaner. When not in use, the cleaner should be stored in a clean, dry
place.
10
Dust Bag
Dust bags play a very important role in the efficiency of a vacuum cleaner.The purpose
of the dust bag is to trap dirt. But at the same time the bag fabric must be porous
enough to allow air to pass through. If the bag fabric becomes clogged, no air can
pass through the cleaner and no cleaning can take place regardless of how powerful
the unit is. To keep the cleaner operating at maximum efficiency, empty the dust bag
frequently. Some fine particles can restrict airflow very quickly and will decrease
performance even before the bag appears to be full. For that reason, when vacuuming
carpet fresheners or cleaners, powder, plaster dust, or similar fine substances, the
bag may need to be emptied more often.
How To Empty Dust Bag
NOTE: Turn off the switch and unplug the electrical cord before servicing the
bag. Never operate the vacuum cleaner without the dust bag.
C
B
1. Pull bag out open end of clamp
4. Insert bag adapter clip (B) into bag
adapter retainer (C)
E
5. Push bag collar up and forward so
locator lug (D) slides into slot (E)
6. Turn cam latch to lock bag collar
onto shoulder rivet
A
D
7. Fold top of bag and slide back into
clamp
2. Turn cam latch (A) on bag collar to
release
NOTE: Never wash or dry-clean
cloth bag.
3. Place top of bag into appropriate
container.Hold bag collar and shake
vigorously several times. (Bag can
be turned wrong side out and
brushed with a whisk broom.)
11
Brush Roll Belt
The brush roll belt on the upright vacuum cleaner drives the brush to agitate, sweep,
and comb the carpet nap. The belt should be checked regularly to be sure it is in good
condition. Replace the belt if it is stretching, cracking, or slipping. Cut away any hair or
thread wound around the brush roll or the belt pulley because the buildup could cause
the belt to rotate unevenly.
How to Replace A Worn Belt
NOTE: Turn off the switch and unplug the electrical cord before replacing belt.
Belt pulleys can become hot during normal use. To prevent burns, avoid
touching the belt pulley when servicing the drive belt.
IMPORTANT: Improper installation of the brush roll or brush roll belt could cause
carpet or cleaner damage.
Fan Cover
Belt
guide
Motor Pulley
1. Release cam locks to remove
bottom plate.
2. Pull up on belt to rotate it off the
motor pulley. Lift up on brush roll
and remove worn belt.
Brush Roll Pulley
Check for brush wear (see Brush Roll
instructions).
3. Place new belt around brush roll.
4. Align brush roll pulley with belt
guide.
5. Place rubber end cap covers over
both end caps (flat side against
end cap). Align holes and secure.
6. Align end caps with slots in
cleaner base. Push brush roll into
base.
8
8
7. Place lower side of belt into belt
guide and pull to stretch the belt
around the left side of motor
pulley. Rotate pulley to secure belt
into groove.
Ask for GENUINE EUREKA
8. Place slots of bottom plate over
tabs of cleaner base. Seat and
secure cam locks (refer to 1).
replacement belts - No. 52100.
GENUINE
EUREKA PRODUCT
Look for the
symbol.
12
Brush Roll
The rotating brush roll sweeps and combs the carpet nap. Keep the brush roll free
from hair and threads so it will continue brushing the carpet nap. Replace worn brush
strips when the bristles no longer touch a piece of cardboard held across the bottom
plate. There are two types of brush rolls, the chromed steel tubular brush roll or the
anodized aluminum spiral brush roll. Follow the instructions for the type of brush roll
featured on the cleaner.
NOTE: Turn off the switch and unplug the electrical cord before replacing brush
strips.
How To Replace Worn Brush Strips (chromed steel tubular)
New brush strips are supplied in sets of two, one long and one short. To replace,
remove bottom plate and belt (see How To Change Belt). Then, grasp center of brush
roll and lift to remove.
F
E
A
B
C
D
D
A. Remove rubber end cap cover from
one end
B. Unscrew locknut
F. Slide in new brush strip of same length
(rounded end first) Fit track on either
side into brush roll slot.
C. Remove end cap
Replace second brush strip from
opposite end of brush roll.
E. Replace shaft
D. Align indentation on bearing retainer
with brush strip on both ends of brush
roll
(sleeve bearing brush roll
assembly includes a shaft washer,
not pictured)
D.
Remove bearing retainer
E. Push shaft through opposite end
F. Pull out worn brush strip with pliers.
(replace shaft washer on sleeve
bearing assembly)
C. Position end cap with flat sides of
center hole over flat sides of threaded
shaft
B. Tighten locknut
A. Align holes and secure rubber end cap
cover flat side against end cap
When properly assembled, the brush roll should rotate freely between the two end
caps. Check the condition of the belt; change if necessary. Replace the brush roll, belt,
and bottom plate (see How To Replace A Worn Belt).
Ask for GENUINE EUREKA replacement brush strip
12 inch No. 52282; 16 inch No. 52246-1
13
How To Replace Worn Brush Strips (anodized aluminum spiral)
New brush strip inserts are supplied in sets of two, one long and one short.To replace,
remove bottom plate and belt (see How To Change Belt). Then, grasp center of brush
roll and lift to remove.
A. Remove rubber end cap cover from one
end
B. Unscrew locknut
C. Remove end cap
D. Press down on the brush strip and push
out. Slide in new brush strip of same
A
B
C
length, clip first, until clip locks into place.
Replace second strip from opposite end.
(double bristle brush roll requires two sets
of brush strips.)
CLIP
NOTE: Some models have two rows of bristles.
C. Position end cap so flat side of
center hole is over flat side of
threaded shaft
B. Tighten locknut
A. Align holes and secure rubber end
cap cover (flat side against end cap)
When properly assembled, the brush roll should rotate freely between the two end
caps. Check the condition of the belt; change if necessary. Replace the brush roll, belt,
and bottom plate (see How To Replace A Worn Belt).
Ask for Genuine Eureka replacement brush strip.
12 inch–No. 52140; 16 inch–No. 52264
Order two sets for double bristle brush rolls.
Headlight Bulb (Standard on most models)
NOTE: Turn off the switch and unplug the electrical cord before replacing
headlight bulb.
Headlight style varies by model. Locate the notches that release the tabs at either (1)
top, (2) side, or (3) bottom of the lens, as illustrated. Place a screwdriver into one
notch; twist or pry the screwdriver to release the lens. Repeat for the second notch on
the opposite side.
Rotate the bulb socket forward. Push bulb in and turn to remove. Secure new bulb into
socket and rotate bulb socket backward.
Replace the lens tabs into the top or the bottom of the hood opening. Rotate lens to
position and press down at each notch until the lens locks into position.
NOTE: Use 25 watt replacement bulb, only.
Ask for GENUINE EUREKA replacement bulb, 40009A.
1
2
3
14
THE SANITAIRE® COMMERCIAL
LIMITED WARRANTY
WHAT THIS WARRANTY COVERS
Your Sanitaire commercial cleaner is warranted to be free from
all defects in material and workmanship in normal use FOR A
PERIOD OF ONE YEAR. The warranty is granted only to the
original purchaser of the cleaner. The warranty is subject to the
following provisions.
WHAT THIS WARRANTY DOES NOT COVER
• Parts of the cleaner that require replacement under normal
use, such as bumpers, bags, bristle strips, belts, light bulbs,
hoses, and impellers.
• Damages or malfunctions caused by negligence, abuse, or
use not in accordance with the Owner’s Guide.
• Defects or damages caused by unauthorized service or the
use of other than Genuine Eureka parts.
WHAT THE EUREKA COMPANY WILL DO
The Eureka Company will, at its option, repair or replace a
defective cleaner or cleaner part that is covered by this warranty.
As a matter of warranty policy, the Eureka Company will not
refund the consumer’s purchase price.
WARRANTY REGISTRATION
Please fill out and return the warranty registration card
accompanying your cleaner.
–continued on reverse side–
15
OBTAINING WARRANTY SERVICE
To obtain warranty service you must return the defective cleaner or cleaner
part along with proof of purchase to any Eureka/Sanitaire Authorized Warranty
Station. You will find the nearest location in the Yellow Pages under “Vacuum
Cleaners–Service and Repair.” Be certain that the Warranty Station is “Eureka/
Sanitaire Authorized”.
For the location of the nearest Eureka/Sanitaire Authorized Warranty Station
or for service information, telephone toll free:
USA: 1-800-282-2886
Mexico: 5670-6169
Canada: 1-800-282-2886
If you prefer, you can write to:
The Eureka Company
Service Division
In Canada write to:
The Eureka Company
866 Langs Drive
807 North Main Street
Bloomington, IL 61701, USA
Cambridge, Ontario N3H 2N7
If it is necessary to ship the cleaner outside your community to obtain warranty
repair, you must pay the shipping charges to the Eureka/Sanitaire Authorized
Warranty Station.Return shipping charges will be paid by theWarranty Station.
When returning parts for repair, please include the model, type, and serial
numbers from the data plate on the cleaner.
FURTHER LIMITATIONS AND EXCLUSIONS
Any warranty that may be implied in connection with your purchase or use
of the cleaner, including any warranty of MERCHANTABILITY or any warranty
for FITNESS FOR A PARTICULAR PURPOSE is limited to the duration of this
warranty.Some states do not allow limitations on how long an implied warranty
lasts, so the above limitations may not apply to you.
Your relief for the breach of this warranty is limited to the relief expressly
provided above. IN NO EVENT SHALL EUREKA BE LIABLE FOR ANY
CONSEQUENTIAL OR INCIDENTAL DAMAGES THAT YOU MAY INCUR IN
CONNECTION WITHYOUR PURCHASE OR USE OF THE CLEANER. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights.You may also have other rights
which vary by State.
THE EUREKA COMPANY
Bloomington, Illinois 61701
©1999 White Consolidated, Ltd.
Part No. 55586E (4/02)
Printed in U.S.A.
|